DNBSEQ-E25RS High-throughput Sequencing Set (FCL SE100)
940-000570-00 |
DNBSEQ-E25RS High-throughput Sequencing Kit (FCL SE100) |
930-000045-00 |
DNBSEQ-E25RS Sequencing Flow Cell |
DNBSEQ-E25RS High-throughput Sequencing Set (FCL PE150)
940-000571-00 |
DNBSEQ-E25RS High-throughput Sequencing Kit (FCL PE150) |
930-000045-00 |
DNBSEQ-E25RS Sequencing Flow Cell |
DNBSEQ-E25RS High-throughput Sequencing Set (App-C FCL SE100)
940-000572-00 |
DNBSEQ-E25RS High-throughput Sequencing Kit (App-C FCL SE100) |
930-000045-00 |
DNBSEQ-E25RS Sequencing Flow Cell
|
DNBSEQ-E25RS High-throughput Sequencing Set (App-C FCL PE150)
940-000568-00 |
DNBSEQ-E25RS High-throughput Sequencing Kit (App-C FCL PE150)
|
930-000045-00 |
DNBSEQ-E25RS Sequencing Flow Cell |
Features
Easy to operate DNB loading and sequencing can be done with only one sample injection. | Easy to maintain Reagents enter flow cell directly from reagent cartridge, no instrument wash required between runs. |
Simplified sequencing process Sequencing set has one-step DNB making reagent, which can direct access to DNB samples. | Seamless conversion Reagents used for library conversion, one-step DNB making and sequencing cartridge with pre-filled primers are all included, enabling sequencing of third-party libraries without purchasing additional reagents. |
DNB loading and sequencing can be done with only one sample injection.
Reagents enter flow cell directly from reagent cartridge, no instrument wash required between runs.
Sequencing set has one-step DNB making reagent, which can direct access to DNB samples.
Product Specification
Read length |
SE100 |
PE150 |
APP-C SE100*** |
App-C PE150*** |
Maximum flow cell number |
1 |
1 |
1 |
1 |
Effective reads/flow cell* |
25 M |
25 M |
20 M |
20 M |
Data output |
2.5 Gb |
7.5 Gb |
2.0 Gb |
6.0 Gb |
Q30** |
>90% |
>80% |
>90% |
>80% |
Run time (DNB-FQ) |
~5 h |
~20 h |
~5 h |
~20 h |
* The effective reads value is obtained according to the operation of a specific standard library, and the actual application library will fluctuate according to the sample type and library construction method. ** The percentage of bases above Q30 and the running time are averaged over the entire run for a particular standard library. The practical application performance is affected by sample type, library quality, insert length and other factors. *** The App-C Sequencing Set includes the invertase module, eliminating the need to purchase additional conversion reagents. **** The existing kit supports SE50 and PE100 reads, and the instrument does not have SE50 and PE100 sequencing modes. |