DNBSEQ-G400RS Stereo-seq Visualization Reagent Set (G400 STO FCL PE75)
DNBSEQ-T7RS Stereo-seq Visualization Reagent Set (T7 STO FCL PE75)
Features
Dual Platform Adapted
Combined with the Stereo-seq library preparation process and based on the Stereo-seq Visualization Reagent Set, both DNBSEQ-T7RS and DNBSEQ-G400RS sequencing platforms can provide excellent sequencing performance. | Highly Integrated The primer and OneStep DNB Make Reagent is pre-placed in the Stereo-seq Visualization Reagent Set to improve ease of use. |
STOmics Libraries Exclusive
Specifically designed for STOmics libraries, compatible with the Stereo-seq OMNI FFPE Chip N Libraries. It is expected to become compatible with Stereo-seq V1.3 Chip T Libraries in the near future. |
Combined with the Stereo-seq library preparation process and based on the Stereo-seq Visualization Reagent Set, both DNBSEQ-T7RS and DNBSEQ-G400RS sequencing platforms can provide excellent sequencing performance.
The primer and OneStep DNB Make Reagent is pre-placed in the Stereo-seq Visualization Reagent Set to improve ease of use.
Specifically designed for STOmics libraries, compatible with the Stereo-seq OMNI FFPE Chip N Libraries. It is expected to become compatible with Stereo-seq V1.3 Chip T Libraries in the near future.
Product Specification
|
DNBSEQ-G400RS Stereo-seq Visualization Reagent Set |
DNBSEQ-T7RS Stereo-seq Visualization Reagent Set |
Read length |
PE75 |
PE75 |
Flow Cell Type |
FCL |
FCL |
Lane No./Flow Cell |
4 |
1 |
Effective reads/Flow Cell* |
1280 M~1800 M |
3500 M~5800 M |
Q30** |
>85% |
>85% |
Run time |
22 h*** |
12 h**** |
* The effective reads value is obtained according to the operation of a specific standard library, and the actual application library will fluctuate according to the sample type and library construction method. ** The percentage of bases above Q30 and the running time are averaged over the entire run for a particular standard library. The practical application performance is affected by sample type, library quality, insert length and other factors. ***Run time is calculated based on dual-slide mode including sample loading, sequencing, base calling, and data processing (From Post loading prime to output FASTQ file). ****Run time includes Flow Cell loading, sequencing, and outputting Cal. File. Cal. is a binary file format generated by MGl sequencer basecall software. |
All-in-one Integrated Kit, Empowering Spatio-temporal Omics Research
For research use only. Not for use in diagnostic procedures.
Stereo-seq FFPE Workflow
Stereo-seq OMNI, a revolutionary sequencing-based spatial transcriptomics solution to study your FFPE samples. It provides true spatial single-cell total RNA information with accuracy and precision with the innovative 'Random Probe' design. Covering a continuous tissue area of 10mm by 10mm, Stereo-seq OMNI delivers best-in-class data and bioinformatics workflow for analyzing spatial total RNA information.
Related Documents
- Materials
- SDS