Go Back / Location:Home / Products

DNBSEQ-G99 High-throughput Sequencing Set

DNBSEQ-G99 High-throughput Sequencing Set(1) is developed based on MGI's core DNBSEQTM  sequencing technology. Novel designed reagent cartridge applies to the sequencing sets. Supporting oncology panel, exome, small genome sequencing and other applications. By adopting the DNBSEQTM technology with the innovative StandardMPS 2.0 sequencing reagents, this upgrade delivers an impressive proportion of 85%* or higher for base quality scores reaching or exceeding Q40* during the sequencing process.


* Q40 (>85%) refers to the sequencing quality for read length of PE150 and below.



DNBSEQ-G99 High-throughput Sequencing Set

DNBSEQ-G99 High-throughput Sequencing Set (StandardMPS 2.0)

Item No.:
940-001268-00
DNBSEQ-G99RS High-throughput Sequencing Reagent Set (G99 FCL SE100/PE50)
940-001269-00
DNBSEQ-G99RS High-throughput Sequencing Reagent Set (G99 FCL PE150)
940-001267-00
DNBSEQ-G99RS High-throughput Sequencing Reagent Set (G99 App-C FCL SE100)
940-001274-00
DNBSEQ-G99RS High-throughput Sequencing Reagent Set (G99 App-C FCL PE150)

>

DNBSEQ-G99 High-throughput Sequencing Set (StandardMPS)

Item No.:
940-000415-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 SM FCL PE300)
940-000409-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 SM FCL SE100/PE50)
940-000410-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 SM FCL PE150)

940-000413-00

DNBSEQ-G99RS High-throughput Sequencing Set (G99 SM App-C FCL PE150)
940-000520-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 SM App-C FCL SE100)
940-000417-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 SM FCL SE400)
940-000624-00
DNBSEQ-G99 Cleaning Reagent Kit (G99 SM FCL)

>

Features

Rapid sequencing
Rapid sequencing
Only 12 hours for PE150 (from loading to FASTQ).
Flexible throughput
Flexible throughput

Independent loading and running of dual flow cells.

Bioinformatics integrated
Bioinformatics integrated

Option to include built-in bioinformatics module to support sequencing and advanced analysis in a single machine.

Rapid sequencing
Rapid sequencing
Only 12 hours for PE150 (from loading to FASTQ).
Flexible throughput
Flexible throughput

Independent loading and running of dual flow cells.

Bioinformatics integrated
Bioinformatics integrated

Option to include built-in bioinformatics module to support sequencing and advanced analysis in a single machine.

Product Specification

Read length
SE100/PE50
PE150
APP-C SE100
APP-C PE150 PE300 SE400
Maximum flow cell number 2 2 2 2 2 2
Effective reads/flow cell*
80 M 80 M
80 M
80 M
80 M 80 M
Data output
8 Gb~16 Gb

24 Gb~48 Gb

8 Gb~16 Gb

24 Gb~48 Gb

48 Gb~96 Gb 32 Gb~64 Gb
Q30**
>90%
>85%
>90%
>85%
>85% >75%
Q40*** >85%
>85%
>85% >85% / /
Run time(DNB-FQ)
5 h

12 h

5 h

12 h

30 h 20 h

* The effective reads value is obtained according to the operation of a specific standard library, and the actual application library will fluctuate according to the sample type and library construction method.

** The percentage of bases above Q30 and the running time are averaged over the entire run for a particular standard library. The practical application performance is affected by sample type, library quality, insert length and other factors.
*** Only StandardMPS 2.0 (SM 2.0) reagents support the generation of Q40 data.

**** The existing kit supports SE50 and PE100 reads, and the instrument does not have SE50 and PE100 sequencing modes.


(1) Unless otherwise informed, this StandardMPS sequencing reagent is not available in Germany, UK, Sweden, and Switzerland.
  • Hotline (Global)
    +86-4000-688-114
  • Email
    MGI-service@mgi-tech.com
  • Special Recommendations
  • *For research use only.

    Not for use in diagnostic procedures (except as specifically noted).
Copyright © 2024 All Rights Reserved MGI Tech Co., Ltd. Guangdong ICP 16117185Privacy PolicyLegal NoticesCookie Policy
Our use of cookies
We would like to use necessary cookies to improve your browsing experience and the quality of our website. We would also like to set analytics cookies and advertisement cookies that help us make improvements by measuring how you use our website. Detailed information about the use of cookies on this website and how you can control your consent can be found in our Cookie Policy and Privacy Policy.
Accept only strictly necessary cookiesAccept all cookies